    冷卻塔安裝要求

    1.冷卻塔安裝要求

    1. Installation requirements of cooling tower
    (1)冷卻塔的安裝應根據設備的各種條件,考慮其安裝位置的地麵及其荷載能力,同時也考慮外界條件。
    (1) The installation of the cooling tower shall consider the ground and its load capacity at the installation locations as well as the external conditions according to various equipment conditions.
    (2)安裝時應注意冷卻塔的基礎按規定的尺寸預埋好水平鋼板,各基礎點的標高應在同一標高的水平麵上。
    (2) During installation, it shall be noted that the horizontal steel plate shall be embedded in the foundation of the cooling tower according to the specified size, and the elevation of each foundation point shall be on the horizontal plane of the same elevation.
    (3)塔體應放置水平。水塔在施工安裝時,為防止壓壞底盤,施工人員應踏在底盤的加強筋上,在安裝塔外殼、底盤等纖維件時,為防止外殼底盤等變形可先穿螺釘,而後依次逐漸緊固,在確認底盤不變形,附近幹淨、幹燥的條件下,為避免使用時漏水可在接觸處鋪設纖維氈及塗樹脂。
    (3) The tower body shall be placed horizontally. During the construction and installation of the water tower, in order to prevent crushing the chassis, the construction personnel should step on the reinforcing ribs of the chassis. When installing the tower shell, chassis and other fiber parts, in order to prevent the deformation of the shell and chassis, the screws can be threaded first, and then the screws can be tightened gradually. After confirming that the chassis is not deformed, and the surrounding area is clean and dry, the fiber felt and resin can be laid at the contact point to avoid water leakage during use.
    2.冷卻塔本體安裝
    2. Installation of cooling tower body
    冷卻塔不得安裝在通風不良和出現濕空氣回流的場合,須安裝在通風良好的場所。否則將會降低冷卻塔的冷卻能力。冷卻塔一般安裝在冷凍站的屋頂上,以形成高壓頭,用以克服冷凝器的阻力損失。水泵將需要處理的冷卻水從水池抽出送至冷卻塔,經冷卻降溫後從塔底集水盤向下自流壓入冷凝器中,並繼而靠水頭壓差自流入水池,如此循環。
    The cooling tower shall not be installed in the place with poor ventilation and wet air return, but in the place with good ventilation. Otherwise, the cooling capacity of the cooling tower will be reduced. The cooling tower is generally installed on the roof of the refrigeration station to form a high-pressure head to overcome the resistance loss of the condenser. The water pump pumps the cooling water to be treated from the pool to the cooling tower. After cooling, it flows down from the water collecting tray at the bottom of the tower to the condenser automatically, and then flows into the pool automatically by the head pressure difference, so as to circulate.
    安裝時,應根據施工圖指明的坐標位置就位,並應找平找正,設備要穩定牢固,冷卻塔的出水管口及噴嘴方向、位置應正確。
    During installation, it shall be in place according to the coordinate position indicated in the construction drawing, and shall be leveled and aligned. The equipment shall be stable and firm, and the direction and position of the water outlet and nozzle of the cooling tower shall be correct.

    相關產品 国产麻豆XXXVIDEO实拍的存在,是為了更好的服務於91无码麻豆视频等可燃氣體淨化及利用行業